Yodify Product Library
Add the Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 to your store or catalog
Book Your Demo and See How
or create your store
Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
Brand: R. STAHL AGThe 9472/35 series 24 V digital input/output module for Zone 2 has 16 channels, which can be used in pairs for operation as inputs for contacts and PNP or NAMUR proximity sensors (EN 60947-5-6) or as outputs for solenoid valves up to 24 V/0.5 A.
Eight inputs can be used for frequencies of up to 20 kHz, and four can be used for detecting the direction of rotation. All inputs/outputs are short-circuit proof and galvanically separated from the system. Additional control input for "System OFF" (IEC61508 / through SIL2)
Features- Sixteen channels can be used in pairs as inputs or outputs (24V/0.5 A)
- Ex nA inputs/outputs with line fault monitoring and LED error and status indication for each channel plus SIL 2 shutdown input
- Module in Zone 2 can be hot swapped
1 - 1 of 1 Part Numbers

230239
Sixteen channels can be used in pairs as inputs or outputs (24V/0.5 A)
Ex nA inputs/outputs with line fault monitoring and LED error and status indication for each channel plus SIL 2 shutdown input
Module in Zone 2 can be hot swapped
Ambient Conditions
- Ambient temperature - -40°C ... +75°C
- Ambient temperature max. - +75°C
- Ambient temperature min. - -40°C
- Max. operating height - < 2000 m
- Max. relative humidity - 95% (without condensation)
- Note - (observe operating instructions)
- Storage temperature - -40°C ... +80°C
- storage temperature °C - -40 - 80 °C
- Storage temperature max. - +80°C
- Storage temperature min. - -40°C
Auxiliary power
- Auxiliary power Version - Intrin. safe Ex ia via BusRail
- Behaviour in case undervoltage - all outputs "OFF"
- Current consumption - 90 mA
- Max. power consumption - 2.20 W
- Power consumption max. - 2.20 W
- Power dissipation max. - output: 5,4 W input: 1,4 W
- Power supply connection - BusRail types 9494
Camera data
- Resolution - 16 Bit / 32 Bit
Device Specific Data
- Counter control - Stop Run Reset
- Counting event - positive slope negative slope
- In. behaviour in case of error - replacement value "1" hold (initial value 1) hold (initial value 0) Replacement value "0"
- Inverting input/output - normal inverted
- LED "System OFF" - LED "24V", yellow
- LED channel error - LED for each channel, red
- LED channel status - LED for each channel, yellow
- LED group error - "ERR" LED, red
- LED operating state - "RUN" LED, green
- LEDmodule requires maintenance - "M/S" LED, blue
- Line fault monitoring - ON OFF
- Module diagnostics message - ON OFF
- Operat.mode counter/frequency - up/down counter 32 bit up/down counter 16 bit Counter 16 bit 1 Hz ... 3 kHz 1 Hz ... 20 kHz with direction 1 Hz ... 20 kHz 0.1 ... 600 Hz
- Pulse extension/freq.filter - 0 s / off 1.2 s / medium 0.6 s / small 2.4 s / large
- Retrievable parameters - hardware revision manufacturer serial number software revision type
- Signal settings note - Settings are made for channel pairs
- Signal status bit - "1" = Output is supplied "0" = Output high-impedance
- Signal type - NAMUR proximity switch / contact; 3-conductor PNP proximity switch; output
Electrical Data
- Number of channels - 16 Ex ec/nA inputs/outputs Adjustable parameters in pairs
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 2
- ATEX gas certificate - DEKRA 16 ATEX 0016 X
- Certificates - ATEX (DEK), Canada (FM), EAC (Sertium), IECEx (DEK), India (PESO), Korea (KTL), USA (FM)
- Ex interface zone - 2
- Gas explosion protection ATEX - II 3 (1) G Ex ec/nA ic [ia Ga] IIC T4 Gc
- Gas explosion protection IECEx - Ex ec/nA ic [ia Ga] IIC T4 Gc
- IECEX gas certificate - IECEx DEK 16.0010X
- Installation - Zone 2
Galvanic isolation
- Aux. power/system components - ≥ 1800 V AC
- I/O channels / ground (PA) - ≥ 1800 V AC
- I/O channels/system components - ≥ 1800 V AC
- Test volt. for gal. separation - acc. to standard EN 60079-11
General
- Functional Description - The 9472/35 series 24 V digital input/output module for Zone 2 has 16 channels, which can be used in pairs for operation as inputs for contacts and PNP or NAMUR proximity sensors (EN 60947-5-6) or as outputs for solenoid valves up to 24 V/0.5 A. Eight inputs can be used for frequencies of up to 20 kHz, and four can be used for detecting the direction of rotation. All inputs/outputs are short-circuit proof and galvanically separated from the system. Additional control input for "System OFF" (IEC61508 / through SIL2)
- Highlights - Sixteen channels can be used in pairs as inputs or outputs (24 V / 0.5 A) Ex nA inputs/outputs with line fault monitoring and LED error and status indication for each channel plus SIL 2 shutdown input Module in Zone 2 can be hot swapped
- Product Description - Remote I/O IS1+ Digital In-/Output Module 24 V for Zone 2 Ex n
- Product Type - 9472/35-16-12
- Title Product Variant Technical Data - 9472/35-16-12 DIOM-24V 16 Z2 Ex n LED
- WebCode - 9472A
Input
- Control input - control input X0
- Control input Function - "Plant STOP" to switch off all outputs
- Control input suitability - Switch-off up to SIL 2, low demand (IEC61508)
- Counting range - 0 ... 65535 as UINT16
- Function - Up/down counter frequency with direction
- hysteresis - ≥ 0,2 mA
- internal resistance - 1
- Max. number counter inputs - 8 (channel 8 ... 15)
- Max. number frequency inputs - 8 (channel 8 ... 15)
- Max. number of 3-wire PNP inputs - 16
- Min. pulse width - 25 Microsecond
- Number of inputs - 16 (NAMUR)
- operating point - 1.65 mA
- Signal input - EN 60947 (NAMUR)
- Supply voltage input - 8 V
- Supply voltage note - ± 5 %
Mechanical Data
- Degree of protection IP (IEC 60529) - IP 20
- Fire resistance (UL 94) - V2
- Height - 67.000 mm
- Length - 128.000 mm
- Module enclosure - Polyamide 6GF
- Pollutant class - Corresponds to G3
- Weight - 0.275 kg
- Width - 96.500 mm
Mounting / Installation
- Mounting position - horizontal vertical
- Mounting type - on DIN rail NS 35/15
- Mounting type 2 - (DIN EN 60715)
Output
- Connectable loads - ohmic inductive capacitive
- Max. number of outputs - 16
- Output current binary - electronically limited
- Supply voltage binary - Corresponds to the ext. supply voltage U H - 0.7 V (X0)
1 - 1 of 1 Part Numbers