Yodify Product Library
Add the Standard Lighting & Heat-Trace Panels Series 8146 to yourĀ store or catalogĀ Ā 
Book Your Demo and See How
or create your store

Standard Lighting & Heat-Trace Panels Series 8146

Brand: R. STAHL AG

R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. 

Customer-specific options are also possible. 

The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. 

The switching position is visible at all times.
Features
  • Standard versions with short delivery times, customer-specific options possible
  • With miniature circuit breaker, tripping characteristic C
  • With residual current circuit breaker with overcurrent release, tripping characteristic C
  • Rated currents 10, 16, 20, 25 A

1 - 12 of 14 Part Numbers
137111
137111
R. STAHL Circuit Distribution Board Light with Miniature Circuit Breaker
Standard versions with short delivery times, customer-specific options possible

With miniature circuit breaker, tripping characteristic C

With residual current circuit breaker with overcurrent release, tripping characteristic C

Rated currents 10, 16, 20, 25 A

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 2 - 6 x Miniature circuit breaker 1-pole 16A / C / 6 kA
  • Entry 1 - 1 x 8161/7-M40-2812
  • Entry 2 - 6 x 8161/7-M25-1707
  • Entry 3 - 1 x 8161/7-M16-0902
  • Locking device present - Yes

Electrical Data

  • Frequency range - 50 - 60 Hz
  • Layout No. - 01
  • Rated operational current - 32.000 A
  • Rated operational voltage AC - 230.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection EAC - Ex e* IIC...IIA T6 ... T4 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T6 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. Customer-specific options are also possible. The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. The switching position is visible at all times.
  • Highlights - Standard versions with short delivery times, customer-specific options possible With miniature circuit breaker, tripping characteristic C With residual current circuit breaker with overcurrent release, tripping characteristic C Rated currents 10, 16, 20, 25 A
  • Product Description - Circuit distribution board light With miniature circuit breaker
  • Product Type - 8146/5-ExV-01-06L16C1P-T
  • Title Product Variant Technical Data - 8146/5-ExV-01-06L16C1P-T stand.licir.dis
  • WebCode - 8146D

Mechanical Data

  • Connection terminals finely-stranded max. - 35.00 mm²
  • Degree of protection (IP) - IP66
  • Degree of protection IP (IEC 60529) - IP66
  • Depth - 190.000 mm
  • Enclosure colour - grey
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Flame retardant acc. - IEC/EN 60695, UL 94, ASTM D635
  • Height - 681.500 mm
  • Impact strength - 7.00 J
  • Weight - 25.000 kg
  • Width - 340.500 mm
137118
137118
R. STAHL Circuit Distribution Board Light with Miniature Circuit Breaker
Standard versions with short delivery times, customer-specific options possible

With miniature circuit breaker, tripping characteristic C

With residual current circuit breaker with overcurrent release, tripping characteristic C

Rated currents 10, 16, 20, 25 A
137124
137124
R. STAHL Circuit Distribution Board Light with Miniature Circuit Breaker
Standard versions with short delivery times, customer-specific options possible

With miniature circuit breaker, tripping characteristic C

With residual current circuit breaker with overcurrent release, tripping characteristic C

Rated currents 10, 16, 20, 25 A

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 2 - 18 x Miniature circuit breaker 1-pole 16A / C / 6 kA
  • Entry 1 - 1 x 8161/7-M50-3516
  • Entry 2 - 18 x 8161/7-M25-1707
  • Entry 3 - 1 x 8161/7-M16-0902
  • Locking device present - Yes

Electrical Data

  • Frequency range - 50 - 60 Hz
  • Layout No. - 03
  • Rated operational current - 80.000 A
  • Rated operational voltage AC - 230.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection EAC - Ex e* IIC...IIA T6 ... T4 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T6 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. Customer-specific options are also possible. The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. The switching position is visible at all times.
  • Highlights - Standard versions with short delivery times, customer-specific options possible With miniature circuit breaker, tripping characteristic C With residual current circuit breaker with overcurrent release, tripping characteristic C Rated currents 10, 16, 20, 25 A
  • Product Description - Circuit distribution board light With miniature circuit breaker
  • Product Type - 8146/5-ExV-03-18L16C1P-T
  • Title Product Variant Technical Data - 8146/5-ExV-03-18L16C1P-T stand.licir.dis
  • WebCode - 8146D

Mechanical Data

  • Connection terminals finely-stranded max. - 35.00 mm²
  • Degree of protection (IP) - IP66
  • Degree of protection IP (IEC 60529) - IP66
  • Depth - 190.000 mm
  • Enclosure colour - grey
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Flame retardant acc. - IEC/EN 60695, UL 94, ASTM D635
  • Height - 681.500 mm
  • Impact strength - 7.00 J
  • Weight - 50.000 kg
  • Width - 681.500 mm
137130
137130
R. STAHL Circuit Distribution Board Light with Miniature Circuit Breaker
Standard versions with short delivery times, customer-specific options possible

With miniature circuit breaker, tripping characteristic C

With residual current circuit breaker with overcurrent release, tripping characteristic C

Rated currents 10, 16, 20, 25 A

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 2 - 24 x Miniature circuit breaker 1-pole 16A / C / 6 kA
  • Entry 1 - 1 x 8161/7-M50-3516
  • Entry 2 - 24 x 8161/7-M25-1707
  • Entry 3 - 1 x 8161/7-M16-0902
  • Locking device present - Yes

Electrical Data

  • Frequency range - 50 - 60 Hz
  • Layout No. - 04
  • Rated operational current - 80.000 A
  • Rated operational voltage AC - 230.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection EAC - Ex e* IIC...IIA T6 ... T4 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T6 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. Customer-specific options are also possible. The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. The switching position is visible at all times.
  • Highlights - Standard versions with short delivery times, customer-specific options possible With miniature circuit breaker, tripping characteristic C With residual current circuit breaker with overcurrent release, tripping characteristic C Rated currents 10, 16, 20, 25 A
  • Product Description - Circuit distribution board light With miniature circuit breaker
  • Product Type - 8146/5-ExV-04-24L16C1P-T
  • Title Product Variant Technical Data - 8146/5-ExV-04-24L16C1P-T stand.licir.dis
  • WebCode - 8146D

Mechanical Data

  • Connection terminals finely-stranded max. - 35.00 mm²
  • Degree of protection (IP) - IP66
  • Degree of protection IP (IEC 60529) - IP66
  • Depth - 240.000 mm
  • Enclosure colour - grey
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Flame retardant acc. - IEC/EN 60695, UL 94, ASTM D635
  • Height - 684.000 mm
  • Impact strength - 7.00 J
  • Weight - 70.000 kg
  • Width - 1236.000 mm
137135
137135
R. STAHL Circuit Distribution Board Light with Miniature Circuit Breaker
Standard versions with short delivery times, customer-specific options possible

With miniature circuit breaker, tripping characteristic C

With residual current circuit breaker with overcurrent release, tripping characteristic C

Rated currents 10, 16, 20, 25 A

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 2 - 6 x Miniature circuit breaker 1-pole 16A / C / 6 kA
  • Entry 1 - 1 x 8161/7-M40-2812
  • Entry 2 - 6 x 8161/7-M25-1707
  • Entry 3 - 1 x 8161/7-M16-0902
  • Locking device present - Yes

Electrical Data

  • Frequency range - 50 - 60 Hz
  • Layout No. - 06
  • Rated operational current - 32.000 A
  • Rated operational voltage AC - 230.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection EAC - Ex e* IIC...IIA T6 ... T4 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T6 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. Customer-specific options are also possible. The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. The switching position is visible at all times.
  • Highlights - Standard versions with short delivery times, customer-specific options possible With miniature circuit breaker, tripping characteristic C With residual current circuit breaker with overcurrent release, tripping characteristic C Rated currents 10, 16, 20, 25 A
  • Product Description - Circuit distribution board light With miniature circuit breaker
  • Product Type - 8146/5-ExV-06-06L16C1P-D
  • Title Product Variant Technical Data - 8146/5-ExV-06-06L16C1P-D stand.licir.dis
  • WebCode - 8146D

Mechanical Data

  • Connection terminals finely-stranded max. - 35.00 mm²
  • Degree of protection (IP) - IP66
  • Degree of protection IP (IEC 60529) - IP66
  • Depth - 190.000 mm
  • Enclosure colour - grey
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Flame retardant acc. - IEC/EN 60695, UL 94, ASTM D635
  • Height - 340.500 mm
  • Impact strength - 7.00 J
  • Weight - 25.000 kg
  • Width - 681.500 mm
137140
137140
R. STAHL Circuit Distribution Board Light with Miniature Circuit Breaker
Standard versions with short delivery times, customer-specific options possible

With miniature circuit breaker, tripping characteristic C

With residual current circuit breaker with overcurrent release, tripping characteristic C

Rated currents 10, 16, 20, 25 A

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 2 - 12 x Miniature circuit breaker 1-pole 16A / C / 6 kA
  • Entry 1 - 1 x 8161/7-M50-3516
  • Entry 2 - 12 x 8161/7-M25-1707
  • Entry 3 - 1 x 8161/7-M16-0902
  • Locking device present - Yes

Electrical Data

  • Frequency range - 50 - 60 Hz
  • Layout No. - 07
  • Rated operational current - 64.000 A
  • Rated operational voltage AC - 230.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection EAC - Ex e* IIC...IIA T6 ... T4 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T6 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. Customer-specific options are also possible. The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. The switching position is visible at all times.
  • Highlights - Standard versions with short delivery times, customer-specific options possible With miniature circuit breaker, tripping characteristic C With residual current circuit breaker with overcurrent release, tripping characteristic C Rated currents 10, 16, 20, 25 A
  • Product Description - Circuit distribution board light With miniature circuit breaker
  • Product Type - 8146/5-ExV-07-12L16C1P-D
  • Title Product Variant Technical Data - 8146/5-ExV-07-12L16C1P-D stand.licir.dis
  • WebCode - 8146D

Mechanical Data

  • Connection terminals finely-stranded max. - 35.00 mm²
  • Degree of protection (IP) - IP66
  • Degree of protection IP (IEC 60529) - IP66
  • Depth - 190.000 mm
  • Enclosure colour - grey
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Flame retardant acc. - IEC/EN 60695, UL 94, ASTM D635
  • Height - 340.500 mm
  • Impact strength - 7.00 J
  • Weight - 37.000 kg
  • Width - 1023.000 mm
137146
137146
R. STAHL Heating Circuit Distribution Boards with Residual Current Circuit Breaker with Overcurrent Release
Standard versions with short delivery times, customer-specific options possible

With miniature circuit breaker, tripping characteristic C

With residual current circuit breaker with overcurrent release, tripping characteristic C

Rated currents 10, 16, 20, 25 A

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 2 - 8 x With residual current circuit breaker 1-pole 16 A+N/30 mA/B/6 kA
  • Entry 1 - 1 x 8161/7-M40-2812
  • Entry 2 - 8 x 8161/7-M25-1707
  • Entry 3 - 1 x 8161/7-M16-0902
  • Locking device present - Yes

Electrical Data

  • Frequency range - 50 - 60 Hz
  • Layout No. - 02
  • Rated operational current - 48.000 A
  • Rated operational voltage AC - 230.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T130 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T130 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T4 Gb
  • Gas explosion protection EAC - Ex e* IIC...IIA T6 ... T4 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. Customer-specific options are also possible. The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. The switching position is visible at all times.
  • Highlights - Standard versions with short delivery times, customer-specific options possible With miniature circuit breaker, tripping characteristic C With residual current circuit breaker with overcurrent release, tripping characteristic C Rated currents 10, 16, 20, 25 A
  • Product Description - Heating circuit distribution boards With residual current circuit breaker With overcurrent release
  • Product Type - 8146/5-ExV-02-08H16B1N-T
  • Title Product Variant Technical Data - 8146/5-ExV-02-08H16B1N-T stand.licir.dis
  • WebCode - 8146D

Mechanical Data

  • Connection terminals finely-stranded max. - 35.00 mm²
  • Degree of protection (IP) - IP66
  • Degree of protection IP (IEC 60529) - IP66
  • Depth - 190.000 mm
  • Enclosure colour - grey
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Flame retardant acc. - IEC/EN 60695, UL 94, ASTM D635
  • Height - 681.500 mm
  • Impact strength - 7.00 J
  • Weight - 37.000 kg
  • Width - 681.500 mm
137152
137152
R. STAHL Heating Circuit Distribution Boards with Residual Current Circuit Breaker with Overcurrent Release
Standard versions with short delivery times, customer-specific options possible

With miniature circuit breaker, tripping characteristic C

With residual current circuit breaker with overcurrent release, tripping characteristic C

Rated currents 10, 16, 20, 25 A

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 2 - 12 x With residual current circuit breaker 1-pole 16 A+N/30 mA/B/6 kA
  • Entry 1 - 1 x 8161/7-M50-3516
  • Entry 2 - 12 x 8161/7-M25-1707
  • Entry 3 - 1 x 8161/7-M16-0902
  • Locking device present - Yes

Electrical Data

  • Frequency range - 50 - 60 Hz
  • Layout No. - 03
  • Rated operational current - 64.000 A
  • Rated operational voltage AC - 230.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T130 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T130 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T4 Gb
  • Gas explosion protection EAC - Ex e* IIC...IIA T6 ... T4 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. Customer-specific options are also possible. The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. The switching position is visible at all times.
  • Highlights - Standard versions with short delivery times, customer-specific options possible With miniature circuit breaker, tripping characteristic C With residual current circuit breaker with overcurrent release, tripping characteristic C Rated currents 10, 16, 20, 25 A
  • Product Description - Heating circuit distribution boards With residual current circuit breaker With overcurrent release
  • Product Type - 8146/5-ExV-03-12H16B1N-T
  • Title Product Variant Technical Data - 8146/5-ExV-03-12H16B1N-T stand.licir.dis
  • WebCode - 8146D

Mechanical Data

  • Connection terminals finely-stranded max. - 35.00 mm²
  • Degree of protection (IP) - IP66
  • Degree of protection IP (IEC 60529) - IP66
  • Depth - 240.000 mm
  • Enclosure colour - grey
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Flame retardant acc. - IEC/EN 60695, UL 94, ASTM D635
  • Height - 684.000 mm
  • Impact strength - 7.00 J
  • Weight - 50.000 kg
  • Width - 1236.000 mm
137157
137157
R. STAHL Heating Circuit Distribution Boards with Residual Current Circuit Breaker with Overcurrent Release
Standard versions with short delivery times, customer-specific options possible

With miniature circuit breaker, tripping characteristic C

With residual current circuit breaker with overcurrent release, tripping characteristic C

Rated currents 10, 16, 20, 25 A

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 2 - 24 x With residual current circuit breaker 1-pole 16 A+N/30 mA/B/6 kA
  • Entry 1 - 1 x 8161/7-M50-3516
  • Entry 2 - 24 x 8161/7-M25-1707
  • Entry 3 - 1 x 8161/7-M16-0902
  • Locking device present - Yes

Electrical Data

  • Frequency range - 50 - 60 Hz
  • Layout No. - 05
  • Rated operational current - 80.000 A
  • Rated operational voltage AC - 230.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T130 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T130 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T4 Gb
  • Gas explosion protection EAC - Ex e* IIC...IIA T6 ... T4 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. Customer-specific options are also possible. The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. The switching position is visible at all times.
  • Highlights - Standard versions with short delivery times, customer-specific options possible With miniature circuit breaker, tripping characteristic C With residual current circuit breaker with overcurrent release, tripping characteristic C Rated currents 10, 16, 20, 25 A
  • Product Description - Heating circuit distribution boards With residual current circuit breaker With overcurrent release
  • Product Type - 8146/5-ExV-05-24H16B1N-T
  • Title Product Variant Technical Data - 8146/5-ExV-05-24H16B1N-T stan.ht.cir.dis
  • WebCode - 8146D

Mechanical Data

  • Connection terminals finely-stranded max. - 35.00 mm²
  • Degree of protection (IP) - IP66
  • Degree of protection IP (IEC 60529) - IP66
  • Depth - 240.000 mm
  • Enclosure colour - grey
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Flame retardant acc. - IEC/EN 60695, UL 94, ASTM D635
  • Height - 684.000 mm
  • Impact strength - 7.00 J
  • Weight - 95.000 kg
  • Width - 1578.000 mm
137161
137161
R. STAHL Heating Circuit Distribution Boards with Residual Current Circuit Breaker with Overcurrent Release
Standard versions with short delivery times, customer-specific options possible

With miniature circuit breaker, tripping characteristic C

With residual current circuit breaker with overcurrent release, tripping characteristic C

Rated currents 10, 16, 20, 25 A

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 2 - 8 x With residual current circuit breaker 1-pole 16 A+N/30 mA/C/6 kA
  • Entry 1 - 1 x 8161/7-M40-2812
  • Entry 2 - 8 x 8161/7-M25-1707
  • Entry 3 - 1 x 8161/7-M16-0902
  • Locking device present - Yes

Electrical Data

  • Frequency range - 50 - 60 Hz
  • Layout No. - 02
  • Rated operational current - 48.000 A
  • Rated operational voltage AC - 230.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T130 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T130 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T4 Gb
  • Gas explosion protection EAC - Ex e* IIC...IIA T6 ... T4 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. Customer-specific options are also possible. The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. The switching position is visible at all times.
  • Highlights - Standard versions with short delivery times, customer-specific options possible With miniature circuit breaker, tripping characteristic C With residual current circuit breaker with overcurrent release, tripping characteristic C Rated currents 10, 16, 20, 25 A
  • Product Description - Heating circuit distribution boards With residual current circuit breaker With overcurrent release
  • Product Type - 8146/5-ExV-02-08H16C1N-T
  • Title Product Variant Technical Data - 8146/5-ExV-02-08H16C1N-T stan.ht.cir.dis
  • WebCode - 8146D

Mechanical Data

  • Connection terminals finely-stranded max. - 35.00 mm²
  • Degree of protection (IP) - IP66
  • Degree of protection IP (IEC 60529) - IP66
  • Depth - 190.000 mm
  • Enclosure colour - grey
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Flame retardant acc. - IEC/EN 60695, UL 94, ASTM D635
  • Height - 681.500 mm
  • Impact strength - 7.00 J
  • Weight - 37.000 kg
  • Width - 681.500 mm
137164
137164
R. STAHL Heating Circuit Distribution Boards with Residual Current Circuit Breaker with Overcurrent Release
Standard versions with short delivery times, customer-specific options possible

With miniature circuit breaker, tripping characteristic C

With residual current circuit breaker with overcurrent release, tripping characteristic C

Rated currents 10, 16, 20, 25 A

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 2 - 12 x With residual current circuit breaker 1-pole 16 A+N/30 mA/C/6 kA
  • Entry 1 - 1 x 8161/7-M50-3516
  • Entry 2 - 12 x 8161/7-M25-1707
  • Entry 3 - 1 x 8161/7-M16-0902
  • Locking device present - Yes

Electrical Data

  • Frequency range - 50 - 60 Hz
  • Layout No. - 03
  • Rated operational current - 64.000 A
  • Rated operational voltage AC - 230.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T130 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T130 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T4 Gb
  • Gas explosion protection EAC - Ex e* IIC...IIA T6 ... T4 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. Customer-specific options are also possible. The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. The switching position is visible at all times.
  • Highlights - Standard versions with short delivery times, customer-specific options possible With miniature circuit breaker, tripping characteristic C With residual current circuit breaker with overcurrent release, tripping characteristic C Rated currents 10, 16, 20, 25 A
  • Product Description - Heating circuit distribution boards With residual current circuit breaker With overcurrent release
  • Product Type - 8146/5-ExV-03-12H16C1N-T
  • Title Product Variant Technical Data - 8146/5-ExV-03-12H16C1N-T stan.ht.cir.dis
  • WebCode - 8146D

Mechanical Data

  • Connection terminals finely-stranded max. - 35.00 mm²
  • Degree of protection (IP) - IP66
  • Degree of protection IP (IEC 60529) - IP66
  • Depth - 240.000 mm
  • Enclosure colour - grey
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Flame retardant acc. - IEC/EN 60695, UL 94, ASTM D635
  • Height - 684.000 mm
  • Impact strength - 7.00 J
  • Weight - 50.000 kg
  • Width - 1236.000 mm
137167
137167
R. STAHL Heating Circuit Distribution Boards with Residual Current Circuit Breaker with Overcurrent Release
Standard versions with short delivery times, customer-specific options possible

With miniature circuit breaker, tripping characteristic C

With residual current circuit breaker with overcurrent release, tripping characteristic C

Rated currents 10, 16, 20, 25 A

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 2 - 24 x With residual current circuit breaker 1-pole 16 A+N/30 mA/C/6 kA
  • Entry 1 - 1 x 8161/7-M50-3516
  • Entry 2 - 24 x 8161/7-M25-1707
  • Entry 3 - 1 x 8161/7-M16-0902
  • Locking device present - Yes

Electrical Data

  • Frequency range - 50 - 60 Hz
  • Layout No. - 05
  • Rated operational current - 80.000 A
  • Rated operational voltage AC - 230.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI), USA (FM)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T130 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T130 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T4 Gb
  • Gas explosion protection EAC - Ex e* IIC...IIA T6 ... T4 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. Customer-specific options are also possible. The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. The switching position is visible at all times.
  • Highlights - Standard versions with short delivery times, customer-specific options possible With miniature circuit breaker, tripping characteristic C With residual current circuit breaker with overcurrent release, tripping characteristic C Rated currents 10, 16, 20, 25 A
  • Product Description - Heating circuit distribution boards With residual current circuit breaker With overcurrent release
  • Product Type - 8146/5-ExV-05-24H16C1N-T
  • Title Product Variant Technical Data - 8146/5-ExV-05-24H16C1N-T stan.ht.cir.dis
  • WebCode - 8146D

Mechanical Data

  • Connection terminals finely-stranded max. - 35.00 mm²
  • Degree of protection (IP) - IP66
  • Degree of protection IP (IEC 60529) - IP66
  • Depth - 240.000 mm
  • Enclosure colour - grey
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Flame retardant acc. - IEC/EN 60695, UL 94, ASTM D635
  • Height - 684.000 mm
  • Impact strength - 7.00 J
  • Weight - 95.000 kg
  • Width - 1578.000 mm
1 - 12 of 14 Part Numbers

Documentation

Instantly populate your store or catalogĀ 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more