Yodify Product Library
Add the P8S Sensors Continuous Position Sensor (CPS) to your store or catalog
Book Your Demo and See How
or create your store
P8S Sensors Continuous Position Sensor (CPS)
Brand: Parker ORIGA CorporationMany applications require more than just end of stroke sensing of an actuator, but traditional methods of continuous sensing are expensive to implement.
Parker’s CPS (Continuous Position Sensor) enables quick, precise and contactless continuous position sensing of a magnetic piston.
CPS sensors continuously supply data via analog outputs or IO-Link. Analog position sensors have a voltage output of 0 V ... 10 V as well as a current output of 4 mA ... 20 mA.
CPS enables flexible machine concepts, making it possible to solve tasks in areas such as quality monitoring and process control in conjunction with pneumatic cylinders.
This continuous transfer of position data upgrades the functionality of the pneumatic cylinders by making them more intelligent, and as a result, more versatile.
CPS settings can be adjusted during or after installation using a teach button or using IO-Link.
CPS can be mounted directly in standard T-slots without the need for additional accessories.
Mounting on other cylinder types, (round, tie rod) is possible with adapters.
Features- Continuous position sensing
- IO-Link communication with M12 connector
- No modification to the actuator
- Analog version with M8 connector
- 5 sizes with sensing ranges from 32 mm to 256 mm
- IP67 design suitable for any industrial application
- Yellow teach button for easy set-up
1 - 10 of 10 Part Numbers
1 - 10 of 10 Part Numbers
Specifications
Brand
Cylinder Type
- Profile with T-slot
Installation
- Drop in, fixed by allen key 1.5 mm
Measuring Range
- 32 to 256 mm depending on Type
- (± 1 mm)
Housing Length
- 45 to 269 mm depending on Type
Output Function
- Analog
- IO-Link
Analog Output (Voltage)
- 0-10 V
Analog Output (Current)
- 4-20 mA
Teach-in
- Yes
Enclosure Rating
- IP67 (According to EN 60529)
Supply Voltage
- 15 to 30 Vdc
- (Reverse-Polarity Protected, Operation in short-Circuit Protected network: Max. 8 A)
Power Consumption
- < = 22 mA (Analog)
- < = 25 ma (IO-Link)
- (Without load)
Maximum Load Resistance
- < = 500 Ω
- (Power output, at 24 V)
Min Load Resistance
- < = 2 k Ω
- (Voltage output)
Protection Class
- III
Time Delay Before Availability
- 1.5 s
Required Magnetic Field Sensitivity
- 3 mT / 2 mT (Analog)
- 3 mT (IO-Link)
Resolution
- (FSR: Full Scale Range, Max. Measuring Range)
- 0.03 % Full Scale Range (Max. > =0.05 mm)
Linearity Error
- (At 25° C, linearity error (Maximum deviation) depending on response curve and minimal deviation function.)
- 0.3 mm
Repeat Accuracy
- (At 25° C, repeatability magnet movement in one direction.)
- 0.06 % Full Scale Range (> = 0.1 mm)
Sampling Rate
- (Only in Standard mode, not in IO-Link mode.)
- 1 ms
Indication LED Color
- Yellow (Analog)
Reserve Polarity Protection
- Yes (Analog)
Short Circuit Protection
- Yes (Analog)
Ambient Operating Temperature Range
- -20° to +70° C (PUR cable)
Shock & Vibration Resistance
- 30 g 11 ms / 10 … 55 Hz, 1 mm
EMC
- According to EN 60947-5-2
- (The analogue measured value can deviate under Transient conditions)
International Standard
- CCC (Not applicable)
- CE
- C UL US
- RoHs
- IO-Link
UL File No
- On Request
Housing Material
- Plastic Polyamid PA12
Screw Material
- Stainless Steel
Cable Material
- PUR (Polyurethane)
Conductor Cross-Section
- 0.08 mm²
Connector
- M12 (IO-Link) or M8 (Analog)