Yodify Product Library
Add the Socket for CPU & Power Module Series 9490 to your store or catalog
Book Your Demo and See How
or create your store
Socket for CPU & Power Module Series 9490
Brand: R. STAHL AGThe 9490 series socket is used to install 9440/12 series IS1+ CPM in Zone 1 and for Ex i fieldbus connection.
Single and redundant systems are possible.
The socket contains an LCD for assistance during commissioning and troubleshooting to signal level.
An innovative mechanism enables the CPM to be connected and disconnected (i.e. hot swapped) during operation in Zone 1.
Features- For single or redundant installation of the 9440/22 series CPM in Zone 1
- LCD for locally displaying diagnostic data, input and output values
- passive design boasting high availability
1 - 5 of 5 Part Numbers
.png)
162703
For single or redundant installation of the 9440/22 series CPM in Zone 1
LCD for locally displaying diagnostic data, input and output values
passive design boasting high availability
Ambient Conditions
- Ambient temperature - -20 °C ... +65 °C
- Ambient temperature max. - +65 °C
- Ambient temperature min. - -20 °C
Auxiliary power
- Nominal voltage - 60 V AC
Explosion Protection
- Application range (zones) - 1, 2, 21, 22
- ATEX gas certificate - KEMA 02 ATEX 1333 X
- Certificates - Canada (FM), USA (FM)
- Ex interface zone - 1, 2, 21, 22
- Gas explosion protection ATEX - II 2 G Ex d e [ia] [ib] IIC T4 Gb
- Gas explosion protection IECEx - Ex d e [ia] [ib] IIC T4 Gb
- IECEX gas certificate - IECEx KEM 08.0038X
- Ship approval - CCS, DNVGL
General
- Description - Zone 1, connection by means of Ex e terminals for digital output module relay Art. no. 162627
- Functional Description - The 9490 series socket is used to install 9440/12 series IS1+ CPM in Zone 1 and for Ex i fieldbus connection. Single and redundant systems are possible. The socket contains an LCD for assistance during commissioning and troubleshooting to signal level. An innovative mechanism enables the CPM to be connected and disconnected (i.e. hot swapped) during operation in Zone 1.
- Highlights - Installation in Zone 1, connection by means of Ex e terminals LCD for locally displaying diagnostic data, input and output values passive design boasting high availability
- Product Description - Remote I/O IS1 Base for digital output Module relay
- Product Type - 9490/11-33
- Product Variant - Socket for Digital Output Module Relay
- Title Product Variant Technical Data - 9490/11-33 socket f. 9477 60V/8 chanel
- Version 2 - Using Ex e terminals
- WebCode - 9490A
Mechanical Data
- Version - Connection
- Weight - 0.560 kg
.png)
162705
For single or redundant installation of the 9440/22 series CPM in Zone 1
LCD for locally displaying diagnostic data, input and output values
passive design boasting high availability
Ambient Conditions
- Ambient temperature - -20 °C ... +65 °C
- Ambient temperature max. - +65 °C
- Ambient temperature min. - -20 °C
Auxiliary power
- Nominal voltage - 250 V AC
Explosion Protection
- Application range (zones) - 1, 2, 21, 22
- ATEX gas certificate - KEMA 02 ATEX 1333 X
- Certificates - Canada (FM), USA (FM)
- Ex interface zone - 1, 2, 21, 22
- Gas explosion protection ATEX - II 2 G Ex d e [ia] [ib] IIC T4 Gb
- Gas explosion protection IECEx - Ex d e [ia] [ib] IIC T4 Gb
- IECEX gas certificate - IECEx KEM 08.0038X
- Ship approval - CCS, DNVGL
General
- Description - Zone 1, connection by means of Ex e terminals for digital output module relay Art. no. 162630
- Functional Description - The 9490 series socket is used to install 9440/12 series IS1+ CPM in Zone 1 and for Ex i fieldbus connection. Single and redundant systems are possible. The socket contains an LCD for assistance during commissioning and troubleshooting to signal level. An innovative mechanism enables the CPM to be connected and disconnected (i.e. hot swapped) during operation in Zone 1.
- Highlights - For single or redundant installation of the 9440/22 series CPM in Zone 1 LCD for locally displaying diagnostic data, input and output values passive design boasting high availability
- Product Description - Remote I/O IS1 Base for digital output Module relay
- Product Type - 9490/11-34
- Product Variant - Socket for Digital Output Module Relay
- Title Product Variant Technical Data - 9490/11-34 socket f. 9477 250V/6 chanel
- Version 2 - Using Ex e terminals
- WebCode - 9490A
Mechanical Data
- Version - Connection
- Weight - 0.527 kg
.png)
162707
For single or redundant installation of the 9440/22 series CPM in Zone 1
LCD for locally displaying diagnostic data, input and output values
passive design boasting high availability
Ambient Conditions
- Ambient temperature - -20 °C ... +65 °C
- Ambient temperature max. - +65 °C
- Ambient temperature min. - -20 °C
Auxiliary power
- Nominal voltage - 24 V DC, 120 / 230 V AC
Explosion Protection
- Application range (zones) - 1, 2, 21, 22
- ATEX gas certificate - KEMA 02 ATEX 1333 X
- Certificate EAC - TS RU S-DE.GB04.B.00448
- Certificates - ATEX (DEK), Brazil (ULB), Canada (CSA), Canada (FM), EAC (STV), IECEx (DEK), Korea (KTL), USA (FM)
- Ex interface zone - 1, 2, 21, 22
- Gas explosion protection ATEX - II 2 G Ex d e [ia] [ib] IIC T4 Gb
- Gas explosion protection EAC - 1 Ex d e [ia Ga] [ib] IIC T4 Gb X
- Gas explosion protection IECEx - Ex d e [ia] [ib] IIC T4 Gb
- IECEX gas certificate - IECEx KEM 08.0038X
- Ship approval - ABS, CCS, ClassNK, DNVGL, RINA
General
- Description - Zone 1 connection by means of Ex e terminals 24 V DC, 120 / 230 V AC
- Functional Description - The 9490 series socket is used to install 9440/12 series IS1+ CPM in Zone 1 and for Ex i fieldbus connection. Single and redundant systems are possible. The socket contains an LCD for assistance during commissioning and troubleshooting to signal level. An innovative mechanism enables the CPM to be connected and disconnected (i.e. hot swapped) during operation in Zone 1.
- Highlights - For single or redundant installation of the 9440/22 series CPM in Zone 1 LCD for locally displaying diagnostic data, input and output values passive design boasting high availability
- Product Description - Remote I/O IS1 Base for CPU & Power module
- Product Type - 9490/11-12
- Product Variant - Socket for CPU and Power Module Series 9490
- Title Product Variant Technical Data - 9490/11-12 socket f. 9440/22
- Version 2 - Using Ex e terminals
- WebCode - 9490A
Mechanical Data
- Version - Connection
- Weight - 0.482 kg
.png)
162711
For single or redundant installation of the 9440/22 series CPM in Zone 1
LCD for locally displaying diagnostic data, input and output values
passive design boasting high availability
Ambient Conditions
- Ambient temperature - -20 °C ... +65 °C
- Ambient temperature max. - +65 °C
- Ambient temperature min. - -20 °C
Auxiliary power
- Nominal voltage - 24 V DC, 120 / 230 V AC
Explosion Protection
- Application range (zones) - 1
- ATEX gas certificate - KEMA 02 ATEX 1333 X
- Certificate EAC - TS RU S-DE.GB04.B.00448
- Certificates - ATEX (DEK), Brazil (ULB), EAC (STV), IECEx (DEK), Korea (KTL)
- Gas explosion protection ATEX - II 2 G Ex d e [ia] [ib] IIC T4 Gb
- Gas explosion protection EAC - 1 Ex d mb [ia Ga] [ib] IIC T4 Gb X
- Gas explosion protection IECEx - Ex d e [ia] [ib] IIC T4 Gb
- IECEX gas certificate - IECEx KEM 08.0038X
- Ship approval - ABS, CCS, ClassNK, DNVGL, RINA
General
- Description - Zone 1, connection via pig tail 24 V DC, 120 / 230 V AC
- Functional Description - The 9490 series socket is used to install 9440/12 series IS1+ CPM in Zone 1 and for Ex i fieldbus connection. Single and redundant systems are possible. The socket contains an LCD for assistance during commissioning and troubleshooting to signal level. An innovative mechanism enables the CPM to be connected and disconnected (i.e. hot swapped) during operation in Zone 1.
- Highlights - For single or redundant installation of the 9440/22 series CPM in Zone 1 LCD for locally displaying diagnostic data, input and output values passive design boasting high availability
- Product Description - Remote I/O IS1 Base for CPU & Power module
- Product Type - 9490/13-12
- Product Variant - Socket for CPU and Power Module Series 9490
- Title Product Variant Technical Data - 9490/13-12 socket Z1 5meter pig tail
- WebCode - 9490A
Mechanical Data
- Version - Connection via unconnected cable end
- Weight - 0.900 kg
.png)
162715
For single or redundant installation of the 9440/22 series CPM in Zone 1
LCD for locally displaying diagnostic data, input and output values
passive design boasting high availability
Ambient Conditions
- Ambient temperature - -20 °C ... +65 °C
- Ambient temperature max. - +65 °C
- Ambient temperature min. - -20 °C
Auxiliary power
- Nominal voltage - 24 V DC, 120 / 230 V AC
Explosion Protection
- ATEX gas certificate - KEMA 02 ATEX 1333 X
- Certificate EAC - TS RU S-DE.GB04.B.00448
- Certificates - ATEX (DEK), Brazil (ULB), Canada (CSA), Canada (FM), IECEx (DEK), USA (FM)
- Gas explosion protection ATEX - II 2 G Ex d e [ia] [ib] IIC T4 Gb
- Gas explosion protection IECEx - Ex d e [ia] [ib] IIC T4 Gb
- IECEX gas certificate - IECEx KEM 08.0038X
- Ship approval - ABS, CCS, ClassNK, DNVGL, RINA
General
- Description - Division 1, connection via conduit*) 24 V DC, 120 / 230 V AC
- Functional Description - The 9490 series socket is used to install 9440/12 series IS1+ CPM in Zone 1 and for Ex i fieldbus connection. Single and redundant systems are possible. The socket contains an LCD for assistance during commissioning and troubleshooting to signal level. An innovative mechanism enables the CPM to be connected and disconnected (i.e. hot swapped) during operation in Zone 1.
- Highlights - For single or redundant installation of the 9440/22 series CPM in Zone 1 LCD for locally displaying diagnostic data, input and output values passive design boasting high availability
- Product Description - Remote I/O IS1 Base for CPU & Power module
- Product Type - 9490/12-12
- Product Variant - Socket for CPU and Power Module Series 9490
- Title Product Variant Technical Data - 9490/12-12 plug f. Div.1 f. CPM 9440/22
- WebCode - 9490A
Mechanical Data
- Version - Connection via a conduit
- Weight - 0.900 kg
1 - 5 of 5 Part Numbers