Yodify Product Library
Add the Model FT2A Thermal Gas Mass Flow Meter to your store or catalog
Book Your Demo and See How
or create your store
Model FT2A Thermal Gas Mass Flow Meter
Brand: Fox Thermal InstrumentsThe Model FT2A has a large selection of communication protocol options available intrinsically (without any other equipment).
Options include: BACnet MS/TP, RS485 Modbus RTU, Profibus-DP, DeviceNet, or Ethernet Modbus TCP.
Features- Measures process gas flow rate/total and temperature
- Standard USB port, optional BACnet MS/TP, RS485 Modbus, Profibus-DP, DeviceNet, or Ethernet Modbus TCP
- Standard on-board display and configuration panel
- Equipped with the Power Pro™ thermal mass flow sensor
- One discrete output is programmable for either pulse (for totalizing flow) or alarms
- One discrete input to reset total or select a different calibration on 2 gas curves
- 4-20 mA output proportional to mass flow rate
- FM and FMc approved for Class I, II, III, Div 2, Groups A, B, C, D, E, F, G, T4 hazardous locations; NEMA 4X approved; Remote NEMA 4X electronics enclosure with explosion proof sensor j-box
- CE Approved
- NIST traceable calibration
- Wide measurement range
- 1% R + 0.2% FS flow accuracy
- 24 VDC or optional 100-240 VAC in local or remote enclosures
- Insertion, Inline & Remote Styles
- USB Port, free FT2A View™ Software
- 2 x 4-20 mA outputs
- FM/FMc approvals
Specifications
Brand
4-20 mA Loop Verification
- Simulation Mode used to Align 4-20 mA Output with the Input to Customer’s PLC/DCS.
Cabling to Remote Enclosure
- 5-Conductor, 18 AWG, Twisted, Shielded, 100 ft max.
Calibration
- Factory Calibration to NIST-Traceable Standards
Enclosure
- FM (U.S.) & FMc (Canadian) Approved for Class I, II, III, Div. 2, Groups A, B, C, D, E, F, G, T4A Hazardous Locations. NEMA 4X & CE Approved. Options: Remote NEMA 4X Electronics Enclosure with Explosion-proof Sensor J-box.
Flow Accuracy
- Inline - ± 1 % of Reading ± 0.2 % of Full Scale. 8 Diameters of Straight, Unobstructed Pipe Upstream & 4 Downstream.
- Insertion - ± 1 % of Reading ± 0.2 % of Full Scale. 15 Diameters of Straight, Unobstructed Pipe Upstream & 10 Downstream.
Flow Range
- Inline - Pipe Size scfmNm³/hour 0.25" 0 - 7.5 0 - 11.8 0.5" 0 - 125 0 - 200 0.75" 0 - 220<
- Insertion - Pipe Size scfmNm³/hour 1.5" (40 mm) 0 - 840 0 - 1,325 2" (50 mm) 0 - 1,400 0 - 2,210 2.5" (63 mm) 0 - 2,0
- Note: Standard Conditions of Air at 70° F & One Atmosphere. Consult Factory for Other Gases, Pipe Sizes, & Flow Ranges Other Than Those Listed.
Flow Rates
- 15 to 60,000 SFPM (0.07 to 280 NMPS) - Air at 70° F (20° C) & 1 ATM
Flow Repeatability
- ± 0.2 % of Full Scale
Flow Response Time
- 0.9 seconds (One Time Constant)
Flow Units (Field Selectable)
- scfm, scfh, NMPS, Nm³/M, Nm³/hour, Nm³/D, NLPS, NLPM, NLPH, MCFD, MSCFD, SCFD, MMSCFD, MMscfm, SMPS, Sm³/hour, LB/S, LB/M, LB/H, LB/D, KG/S, KG/M, KG/H, SLPM, SFPM, MT/H, Sm³/M
Gas Pressure (Maximum)
- Check with Factory for Higher Pressure Options. Note: Pressure Ratings Stated for Temperature of 100° F (38° C).
- Inline - NPT(0.25" - 6"): 500 psig (34.5 barg) 150# Flange: 230 psig (16 barg)
- Insertion - 500 psig (34.5 barg)
Inputs Power (Power Consumption):
- Input Power (without the Anybus Serial Communication Option): 24 Vdc, (± 10 %), 0.4 Amps (Standard DC Power) 100 to 240 Vac ~(+10 %-15 %), 50/60 Hz, 0.2 Amps (with AC Power Option).Input Power (with Anybus Serial Communication Option): 24
Installation
- Inline - Compression Fitting Included with Flow Body
- Insertion - Fox Thermal-supplied Compression Fitting Connects to Customer-supplied 3/4" Female Coupling Welded to Pipe.
Optional Serial Communication
- RS-485 Modbus, BACnet MS/TP, PROFIBUS-DP, DeviceNet or Ethernet Modbus TCP.
Outputs:
- Two Isolated 4-20 mA Outputs (One for Flow Rate & a second is Programmable for Flow Rate or Temperature), Fault Indication Per NAMUR NE43.Isolated Pulse Output 0 to 100 Hz, 5 to 24 Volts P/p for Flow (The Pulse Output Can be used as an Is
Port
- Mini USB Communication Port is Standard.
Relative Humidity
- 90 % RH max.
Retractor Assemblies
- Packing Gland Assembly: 125 psig (8.6 barg) Max. High Pressure (Crank) Retractor: NPT 600 psig (41.4 barg), ANSI 150 Flange & ANSI 300 Flange, No Valve Supplied.
Sensor Material
- 316 Stainless Steel Standard. Hastelloy C-276 Optional.
Software:
- The Free PC-based Software Tool - FT2A View™ - Provides Complete Configuration, Remote Process Monitoring, & Data Logging Functions.
Temperature Accuracy
- ± 1.8° F (± 1.0° C) -40° to 250° F (-40° to 121° C), ± 3.6° F (± 2.0° C), 250° to 650° F (121° to 343° C), 60 SFPM Min..
Temperature by Enclosure
- DC Power: -40° to 158° F (-40° to 70° C) AC Power: -4° to 158° F (-20° to 70° C)
Temperature by Sensor Type
- ST Sensor: -40° to 250° F (-40° to 121° C) HT Sensor: -40° to 650° F (-40° to 343° C)
Turndown
- Up to 1000:1, 100:1 Typical
- Aluminum & Steel Production
- Chemical Plants
- Glass & Ceramics Production
- Pulp & Paper Production
Documentation
Data Sheets
Product Manuals
Document
- FT2A Application Data Sheet (.pdf) 21 KB
- FT2A Application Data Sheet (.xlsx) 40 KB
- FT2A Display Configuration Codes pdf 650 KB
- FT2A Flowmeter Features pdf 194 KB
- FT2A Model Codes pdf 104 KB
- FT2A Procurement Specifications (.docx) 62 KB
- FT2A Procurement Specifications (.pdf) 103 KB
- FT2A Troubleshooting Guide pdf 79 KB